Risk →
| NO RISK
| LOW RISK
| HIGH RISK
|
|
Class →
| 1
| 2
| 3R
| 1M and 2M
| Class 3B
| Class 4
| Reference clause ↓
|
Requirement ↓
| Intrinsic
| Embedded |
LRO needs to be appointed
| -
| -
| -
| -
| -
| √
| √
| 4.2.2
|
Registration
| -
| √
| √
| -
| √
| √
| √
| A14.3
|
Standing orders
| -
| -
| -
| √
| -
| √
| √ | 4.4.1; A7.4.2.3
|
Generic (MHSW 99) risk assessment
| - | √
| √
| -
| √
| -
| -
| A14.1
|
Optical radiation specific risk assessment
| -
| -
| -
| √
| -
| √
| √
| A4
|
Training for normal use
| -
| -
| -
| √
| √
| √
| √
| A17
|
Restricted use of viewing aids
| -
| -
| -
| -
| √
| -
| -
| A7.2.3
|
Conform to basic beam path design principles
| -
| -
| -
| √
| √
| √
| √
| A7.4.3.18 & 19
|
Conform to restricted beam path design principles
| -
| -
| -
| -
| -
| √
| √
| A7.4.3.19
|
Control of specular reflections
| -
| -
| √*
| √
| √*
| √
| √
| A8.3.1 A9.1.7
|
Use of key control
| -
| √
| -
| -
| - | √
| √
| A8.1.5
|
Service and maintenance restrictions
| -
| √
| -
| -
| -
| √
| √
| A8.2
|
Restricted to interlocked laser area
| -
| -
| -
| -
| -
| √
| √
| A7.4
|
Isolation of non-laser activities in normal operation
| -
| -
| -
| -
| -
| √
| √
| A15.5
|
Restricted multiple wavelength operation
| -
| -
| -
| -
| -
| √
| √
| A12
|
Medical examination required in the event of accidental exposure
| -
| -
| -
| -
| -
| √
| √
| A10.1.1
|
Laser safety eyeware to be provided (if identified in risk assessment)
| -
| -
| -
| -
| -
| √
| √
| A11
|
Protective clothing to be provided (if identified in risk assessment)
| -
| -
| -
| -
| -
| -
| √
| A2.1
|
*visible beam lasers only