SC22 Appendix 6
05 Nov 2020
Yes
-  

 

 

Summary of control measures for normal laser operation

No

​​​

 
​Risk →
​NO RISK
​​LOW RISK​
​HIGH RISK

​Class →
​1
​2
​3R
​1M and 2M
​Class 3B
​Class 4
​Reference clause ↓​
​Requirement ​↓
​Intrinsic
Embedded​
​LRO needs to be appointed
​-
​-
​-
​-
​-
​​​​√
​​√
​4.2.2
​Registration
-​
​√
​√
​-
​√
​√
​√
​A14.3
​Standing orders
​-
-​
-​
√​
-​
√​
√​​4.4.1; A7.4.2.3
​Generic (MHSW 99) risk assessment
-​​√
​√
​-
​√
​-
​-
​A14.1
​Optical radiation specific risk assessment
​-
​-
​-
​√
​-
​√
​√
​A4
​Training for normal use
​-
​-
​-
​√
​√
​√
​√
​A17

​Restricted use of viewing aids
​-
​-
​-
​-
​√
​-
​-
​A7.2.3

​Conform to basic beam path design principles
​-
​-
​-
​√
​√
​√
​√
​A7.4.3.18 & 19

​Conform to restricted beam path design principles
​-
​-
​-
​-
​-
​√
​√
​A7.4.3.19

​Control of specular reflections
​-
​-
​√*
​√
​√*
​√
​√
​A8.3.1
A9.1.7

​Use of key control
​-
​√
​-
​-
-​​√
​√
​A8.1.5

​Service and maintenance restrictions
​-
​√
​-
​-
​-
​√
​√
​A8.2

​Restricted to interlocked laser area
​-
​-
​-
​-
​-
​√
​√
​A7.4

​Isolation of non-laser activities in normal operation
​-
​-
​-
​-
​-
​√
​√
​A15.5

​Restricted multiple wavelength operation
​-
​-
​-
​-
​-
​√
​√
​A12

​Medical examination required in the event of accidental exposure
​-
​-​

​-
​-
​-
​√
​√
​A10.1.1

​Laser safety eyeware to be provided (if identified in risk assessment)
​-
​-
​-
​-
​-
​√
​√
​A11

​Protective clothing to be provided (if identified in risk assessment)
​-
​-
​-
​-
​-
​-
​√​
​A2.1

*visible beam lasers only